Installation Instructions
Model Number 1028-04-ANT5-B
(877) 867-2312 www.oberonwireless.com
Rev. A2 01/24/14 Oberon, Inc.
1315 South Allen Street
State College, PA 16801 Copyright 2013
Figure 1
Figure 2
Figure 3
Assembly Components:
- Enclosure Model 1028-04-ANT5-B assembly – 1 each
- 1/2” Trade size hole plugs – 4 each
- 1" Trade size hole plugs – 3 each
- hanger wire – 8 each
- Installation Instructions – 1 each
- #8-32 Nuts – 4 each
- Plastic screw head caps – 4 each
If any of these items are missing, contact your Oberon representative.
Find a flat work surface to assemble the enclosure and any other network/cellular components prior to mounting in ceiling.
Step 1 – Place the enclosure assembly back side down on the work surface and keyed doorway unlocked.
**IMPORTANT** - Determine the correct access point installation method based on the manufacturer.
Step 2a (For Cisco AP’s Only) The mounting studs for Cisco AP’s are located in the bottom of the enclosure. Standard Cisco mounting
brackets as well as “Bracket 2” can be attached so the “Cisco” logo of the AP is parallel to the hinge. For “Bracket 1” the logo of the AP will
be mounted perpendicular to the hinge. Securely fasten the access point’s mounting plate to the mounting holes on the mounting plate of
the enclosure using four (4) #8-32 machine nuts. Attach the Access Point to the mounting plate (Figure 1).
Page 2
Step 2b (Any manufacturer’s access points) Install the provided
“T-Bar” bracket by fastening two (2) #8-32 nuts onto the studs at the
bottom of the enclosure. Attach the access point to the T-Bar bracket
using the manufacturer’s instructions for attaching the access point to
a ceiling tile grid (T-Bar). (Figure 2).
Step 3 (Optional) With the desired number of holes opened, attach antennas
(such as Oberon’s BMANT or DMDUAL) and DAS antennas by inserting the
cables through the door holes. Fasten the antennas to the door per the antenna
manufacturer’s instructions. To retain the water and dust resistance of the
enclosure, antennas should have a gasket to fill the opening. After installation,
connect the RF coax cable from the antenna to the access point (Figure 3). If
using Bulkhead connectors, use Oberon Bulkhead connectors with provided o-
ring (P/N 35-NFBLKHD) to maintain water tightness.
The assembled unit is now ready for ceiling or wall installation.
Page 3
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Installation Instructions

Installation Instructions Model Number 1028-04-ANT5-B (877) 867-2312 • www.oberonwireless.com Rev. A2 01/24/14 Oberon, Inc. •••• 1315 South All

Seite 2 - MODEL 1028-04-ANT5-B

Figure 5 – Snap the Firestop Grommet around the Data Cable and pull through the Conduit Connector as shown. Figure 4 Step 5 – Run the data and pow

Kommentare zu diesen Handbüchern

Keine Kommentare